磁共振胰胆管成像对胰腺分裂症的诊断价值
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Value of magnetic resonance cholangiopancreatography for diagnosis of pancreas divisum
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:比较磁共振胰胆管成像(MRCP) 与内镜逆行胰胆管造影术(ERCP)对胰腺分裂的诊断价值。方法:回顾8例行MRCP及ERCP的胰腺分裂病例,分析比较胰腺分裂MRCP及ERCP的胰胆管表现及MRCP诊断的准确性。结果:8例经ERCP诊断为胰腺分裂的患者中,MRCP诊断的准确性为87.5%(7/8),ERCP显示了所有8例患者的背侧胰管及6例患者的腹侧胰管,MRCP显示8例患者的背侧胰管及3例患者的腹侧胰管。结论:作为一种无创伤性检查,MRCP对胰腺分裂诊断有重要临床价值。

    Abstract:

    Objective:To investigate the value of magnetic resonance cholangiopancreatography(MRCP) in the diagnosis of pancreas divisum by comparing with endoscopic retrograde cholangiopancreatography (ERCP).Methods: The MRCP and ERCP images of 8 patients with pancreas divisum were retrospectively analyzed. The diagnostic accuracy and findings by MRCP were compared with those by ERCP. Results: MRCP had a diagnostic accuracy of 87.5%(7/8) based on the result of ERCP. ERCP displayed the dominant dorsal pancreatic ducts in all 8 cases and ventral pancreatic ducts in 6 cases; MRCP also displayed the dominant dorsal pancreatic ducts in all 8 cases, but the ventral pancreatic ducts only in 3 cases.Conclusion: As a non-invasive technique,MRCP has important clinical value in the diagnosis of pancreas divisum.

    参考文献
    相似文献
    引证文献
相关视频

分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2007-10-15
  • 最后修改日期:2008-02-19
  • 录用日期:2008-06-12
  • 在线发布日期: 2008-06-12
  • 出版日期:
文章二维码
重要通知
友情提醒: 近日发现论文正式见刊或网络首发后,有人冒充我刊编辑部名义给作者发邮件,要求添加微信,此系诈骗行为!可致电编辑部核实:021-81870792。
            《海军军医大学学报》编辑部
关闭