    摘要:

    目的:探讨开胸经导管植入带瓣膜支架置换主动脉瓣膜的可行性及术后短期疗效。方法:新鲜猪心包以0.6%戊二醛浸泡36 h后缝合在瓣膜环上,并将其固定在哑铃型镍钛记忆合金自膨胀支架上,制成带瓣膜主动脉瓣支架。选择健康杂种犬8只,通过开胸穿刺左心室心尖部,超声引导下将带瓣膜支架经导管植入至主动脉瓣处,置换犬自身主动脉瓣膜,术后定期行心电图、心脏彩超、CT及DSA造影检查,随访3个月,观察治疗效果。结果:成功制作带瓣膜主动脉瓣支架,经导管植入置换主动脉瓣膜后5只犬成活;心脏彩超及DSA造影检查证实术后支架位置及瓣膜功能良好,冠脉血流未受影响,术后3个月CT检查未发现支架移位,无明显并发症发生。结论:开胸经导管途径植入自制带瓣膜主动脉瓣支架可有效置换犬主动脉瓣膜,短期随访疗效理想。

    Abstract:

    Objective:To discuss the feasibility of using the off-pump antegrade transventricular route for aortic valved stent implantation in canines,and to observe the short-term outcomes.Methods: Fresh porcine pericardium was treated with 0.6% glutaraldehyde solution for 36 h; then it was trimmed and sutured into a valvular ring and fixed on a new self-expanding dumb-bell-shaped nickel-titanium shape-memory alloy stent.The valved stents were then implanted off-pump in 8 canines.A limited or full sternotomy approach was used to access the apex of the heart.The crimped valve was introduced through a sheath in the left ventricular apex under ultrasound guidance.The function of valved stents was evaluated with electrocardiogram,echocardiography,computed tomography and DSA angiography early and 3 months after the procedure.Results: We successfully prepared the valved aortic stent.Five canines survived after implantation of the aortic valved stents.Angiographic and echocardiographic observation confirmed that the location and function of the stent were satisfactory,without influencing coronary blood flow and mitral valve function.CT examination showed no migration of the stent 3 months after the procedure,and there were no other prominent complications.Conclusion: Our new self-expanding valved stent can be deployed over the native aortic valves via transapical route, and the short-term outcome is satisfactory.

    参考文献
    相似文献
    引证文献
相关视频

分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2009-02-14
  • 最后修改日期:2009-09-06
  • 录用日期:2009-09-25
  • 在线发布日期: 2009-10-26
  • 出版日期:
文章二维码
重要通知
友情提醒: 近日发现论文正式见刊或网络首发后,有人冒充我刊编辑部名义给作者发邮件,要求添加微信,此系诈骗行为!可致电编辑部核实:021-81870792。
            《海军军医大学学报》编辑部
关闭