    摘要:

    目的 设计一种新的视力检测方法——自适应视力检测法,探讨自适应视力检测法的实际应用价值。方法 通过计算机仿真实验考察自适应视力检测法的可行性。以仿真实验为基础,分别用40 trials、80 trials的自适应视力检测法及标准对数视力表(随机次序)对30名受试者[(26.1±4.7)岁,男18名、女12名]进行双眼视力检查。用自适应视力检测法检查结果与标准对数视力表检查结果的一致性限度评价其准确性,用配对样本t检验评价两种检查方法的相关性和差异性。结果 受试者的视力检查结果显示40 trials的自适应视力检测法检查结果与标准对数视力表检查结果间差异无统计学意义,但80 trials的自适应视力检测法检查结果与标准对数视力表检查结果间差异有统计学意义(P<0.05)。结论 在合理的检查次数内(40 trials),自适应视力检测法与标准对数视力表在成人视力检查中一致性较好。与标准对数视力表相比,自适应视力检测法有避免视标记忆问题、减小视觉拥挤效应等优势,具有实际应用价值。

    Abstract:

    Objective To design a new method for visual acuity test naming computerized tumbling E test, and to explore the application of computerized tumbling E test. Methods The feasibility of computerized tumbling E test was investigated by computer simulation experiment. Based on the simulation experiment, a total of 30 subjects ([26.1±4.7] years old, 18 males and 12 females) received binocular vision acuity examination by computerized tumbling E test with 40 trials or 80 trials and standard logarithmic visual acuity chart (random sequence), respectively. The accuracy of computerized tumbling E test was evaluated by comparing the consistency limit with standard logarithmic visual acuity chart. The correlation and difference between the two tests were evaluated by paired samples t test. Results There was no significant difference between the results of the computerized tumbling E test with 40 trials and standard logarithmic visual acuity chart,while the difference between the results of the 80 trials and standard logarithmic visual acuity chart was statistically significant (P<0.05). Conclusion The consistency is good for adult visual test using the computerized tumbling E test with reasonable number of trials (40 trials) and the standard logarithmic visual acuity chart. Compared with the standard logarithmic visual acuity chart, computerized tumbling E test has advantages such as avoiding the problem of optotype memory and reducing the visual crowding effect, showing practical application value (P<0.05).

    参考文献
    相似文献
    引证文献
相关视频

分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2017-03-16
  • 最后修改日期:2017-05-04
  • 录用日期:2017-09-21
  • 在线发布日期: 2017-11-01
  • 出版日期:
文章二维码
重要通知
友情提醒: 近日发现论文正式见刊或网络首发后,有人冒充我刊编辑部名义给作者发邮件,要求添加微信,此系诈骗行为!可致电编辑部核实:021-81870792。
            《海军军医大学学报》编辑部
关闭