巴马小型猪头颈部动脉的磁共振血管成像研究
CSTR:
作者:
作者单位:

第二军医大学长海医院影像医学科,第二军医大学长海医院影像医学科,第二军医大学长海医院影像医学科,第二军医大学长海医院影像医学科,第二军医大学长海医院影像医学科,第二军医大学长海医院影像医学科,第二军医大学长海医院影像医学科,第二军医大学长海医院影像医学科

作者简介:

通讯作者:

中图分类号:

R445.2

基金项目:

国家自然科学基金(31600755,31470910,81400368).


Magnetic resonance angiography for head and neck arteries of Bama minipig
Author:
Affiliation:

Department of Radiology,Changhai Hospital,Second Military Medical University,Department of Radiology,Changhai Hospital,Second Military Medical University,Department of Radiology,Changhai Hospital,Second Military Medical University,Department of Radiology,Changhai Hospital,Second Military Medical University,Department of Radiology,Changhai Hospital,Second Military Medical University,Department of Radiology,Changhai Hospital,Second Military Medical University,Department of Radiology,Changhai Hospital,Second Military Medical University,Department of Radiology,Changhai Hospital,Second Military Medical University

Fund Project:

Supported by National Natural Science Foundation of China (31600755, 31470910, 81400368).

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 利用三维时间飞跃法(3D TOF)和时间分辨对比剂动态显像(TRICKS)磁共振血管成像显示巴马小型猪的头颈部血管结构,并比较分析两种技术的动脉成像指标,为大动物脑血管病模型的研究提供参考。方法 应用3.0 T磁共振仪依次对3只健康巴马小型猪行头颈部血管的3D TOF和TRICKS磁共振血管成像,比较两种磁共振血管成像方法的血管清晰度评分,定量分析主要动脉的对比度(CR)、信噪比(SNR)以及对比噪声比(CNR)。结果 在血管清晰度方面,两种方法对巴马小型猪颈总动脉和颈外动脉系显示较好,对后循环的显示欠佳,而3D TOF磁共振血管成像对颅内动脉系的显示优于TRICKS磁共振血管成像[(1.60±0.50)分vs(1.37±0.49)分,P=0.019 8]。定量分析发现,TRICKS磁共振血管成像可不同程度提高动脉的CR,但两种方法所得动脉的SNR和CNR差异均无统计学意义(P>0.05)。结论 3D TOF和TRICKS磁共振血管成像均可较好地显示巴马小型猪的颈总动脉及其主要分支结构,并各有优势和局限。

    Abstract:

    Objective To display the normal vascular structures of head and neck of Bama minipig by three-dimensional time-of-flight (3D TOF) and time-resolved imaging of contrast kinetics (TRICKS) magnetic resonance angiography (MRA), and to compare and analyze the imaging indicators of arteries, so as to provide references for large animal models of cerebrovascular disease. Methods 3D TOF and TRICKS MRA of head and neck vessels in 3 healthy Bama minipigs were performed using a 3.0 T magnetic resonance system. The artery definition scores of the two MRA methods were compared, and the contrast ratio (CR), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the main arteries were calculated for quantitative analysis. Results In terms of artery definition, 3D TOF MRA and TRICKS MRA both achieved high scores for the common carotid arteries and external carotid arterial system, but low scores for posterior circulation. 3D TOF MRA was significantly better than TRICKS MRA in displaying the intracranial artery system (1.60±0.50 vs 1.37±0.49, P=0.019 8). Quantitative analysis showed that TRICKS MRA improved CR of arteries to different extents; however, there were no significant differences in SNR or CNR between 3D TOF and TRICKS MRA (P>0.05). Conclusion Both 3D TOF and TRICKS MRA have good and comparable diagnostic performance for common carotid arteries and their main branch structures of Bama minipig, and each method has its advantages and limitations.

    参考文献
    相似文献
    引证文献
相关视频

分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2018-03-14
  • 最后修改日期:2018-05-02
  • 录用日期:2018-10-12
  • 在线发布日期: 2018-10-26
  • 出版日期:
文章二维码
重要通知
友情提醒: 近日发现论文正式见刊或网络首发后,有人冒充我刊编辑部名义给作者发邮件,要求添加微信,此系诈骗行为!可致电编辑部核实:021-81870792。
            《海军军医大学学报》编辑部
关闭