国产三维心脏电生理标测系统用于左侧房室旁路射频消融的前瞻性、随机对照研究:经股动脉逆行法与经房间隔穿刺法比较
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

R541.71

基金项目:

国家自然科学基金青年项目(82000283),上海市科技创新行动计划(17DZ1930104).


A prospective, randomized controlled study of a domestic three-dimensional cardiac electrophysiological mapping system for radiofrequency ablation of left-sided accessory pathways: a comparison between retrograde arterial approach and transatrial septal approach
Author:
Affiliation:

Fund Project:

Supported by National Natural Science Foundation of China for Young Scientists (82000283) and Science and Technology Innovation Action Plan of Shanghai (17DZ1930104).

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 探究左侧房室旁路消融经股动脉逆行法与经房间隔穿刺法的优劣及评价国产三维心脏电生理标测系统的性能。方法 采用前瞻性、随机对照研究设计,自2019年7月至2020年8月入选室上性心动过速患者30例,术前行心电生理检查确定为左侧房室旁路并具有导管射频消融适应证,以1∶1的比例将患者随机分配至经股动脉逆行组和经房间隔穿刺组。在国产三维心脏电生理标测系统(Columbus®系统)指导下行左侧房室旁路射频消融术,比较两组患者的靶点标测成功率、术后即刻消融成功率、X线曝光时间、X线辐射剂量、手术时间、术中及术后不良事件的发生率。结果 两组的靶点标测成功率和术后即刻消融成功率均为100%。经房间隔穿刺组的手术时间[(75.40±22.27)min]、X线曝光时间[384(310,510)s]和X线辐射剂量[93(63,123)mGy]与经股动脉逆行组的[(83.80±39.96)min、369(340,989)s和154(56,184)mGy]相比差异均无统计学意义(P均>0.05)。经股动脉逆行组术后不良事件发生率为6.7%(1/15),经房间隔穿刺组无不良事件发生,两组术后不良事件发生率差异无统计学意义(P>0.05)。国产三维心脏电生理标测系统可清晰显影导管电极,导管操作性能良好,能够顺利定位,贴靠满意。结论 国产三维心脏电生理标测系统可安全、有效地用于左侧房室旁路的射频消融,经房间隔穿刺法和经股动脉逆行法2种消融策略在手术时间、X线曝光时间与剂量、不良事件发生率等方面没有区别。

    Abstract:

    Objective To investigate the advantages and disadvantages of retrograde arterial approach and transatrial septal approach for radiofrequency ablation of left-sided accessory pathways, and to evaluate the performance of a domestic three-dimensional (3D) cardiac electrophysiological mapping system. Methods From Jul. 2019 to Aug. 2020, 30 patients with supraventricular tachycardia were enrolled in this prospective, randomized controlled study. The left-sided accessory pathways were determined by cardiac electrophysiological examination before operation and all the patients had the indications for catheter radiofrequency ablation. The patients were randomly assigned to retrograde arterial approach group and transatrial septal approach group at a ratio of 1:1. Under the guidance of a domestic 3D cardiac electrophysiological mapping system (Columbus® system), radiofrequency ablation of left-sided accessory pathways was performed, and the success rate of target mapping, success rate of immediate postoperative ablation, X-ray exposure duration, X-ray radiation dose, operation time and intraoperative and postoperative adverse events were compared between the 2 groups. Results The success rates of target mapping and immediate postoperative ablation were 100% in both groups. The procedure duration ([75.40±22.27] min vs[83.80±39.96]min), X-ray exposure time (384[310, 510]s vs 369[340, 989]s) or X-ray radiation dose (93[63, 123]mGy vs 154[56, 184]mGy) were not significantly different from those of the retrograde arterial approach group (all P>0.05). The incidence of postoperative adverse events was 6.7% (1/15) in the retrograde arterial approach group, and no adverse events occurred in the transatrial septal approach group (P>0.05). The domestic 3D cardiac electrophysiological mapping system could clearly visualize the catheter electrodes. The catheter had good operation performance, could be positioned smoothly, and the attachment was satisfactory. Conclusion The domestic 3D cardiac electrophysiological mapping system can be safely and effectively used for radiofrequency ablation of left-sided accessory pathway ablation. There are no differences in the procedure duration, X-ray exposure time, X-ray radiation dose or incidence of adverse events between transatrial septal approach and retrograde arterial approach.

    参考文献
    相似文献
    引证文献
相关视频

分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-04-06
  • 最后修改日期:2021-10-26
  • 录用日期:
  • 在线发布日期: 2023-03-30
  • 出版日期: 2023-03-20
文章二维码
重要通知
友情提醒: 近日发现论文正式见刊或网络首发后,有人冒充我刊编辑部名义给作者发邮件,要求添加微信,此系诈骗行为!可致电编辑部核实:021-81870792。
            《海军军医大学学报》编辑部