Establishment and evaluation of a cell bubble contact injury model
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

Supported by National Natural Science Foundation of China (81801868, 81971779), Shenlan Project of Naval Medical University (Second Military Medical University) (21TPSL0102) and Combat Foundation of Naval Medical Center of Naval Medical University (Second Military Medical University) (20M0105).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective To establish a cell bubble contact injury model for studying the pathogenesis of bubble-related diseases such as decompression sickness. Methods A cell bubble contact device was designed, including a bubble generating syringe, a cell culture dish, and a punching device. Bubbles with different diameters could be obtained by changing the diameter of the bubble generating syringe end, and the dose-effect relationship between cell damage, bubble diameter and contact time was observed by propidium iodide (PI) staining and cell counting kit 8 (CCK-8) cell viability test in primary cultured rat pulmonary microvascular endothelial cells (PMVECs), so as to establish a stable cell bubble contact injury model. Results The results of PI staining showed that there was no obvious damage to PMVECs after 1, 2, 3, or 4 h of 0.5 mm bubble contacting, while bubbles with diameters of 1.0, 1.5, and 2.0 mm increased the death of PMVECs after contacting 1, 2, 3, and 4 h; and the larger the bubble diameter and the longer the contact time, the more death of PMVECs were. Compared with the control group, CCK-8 cell viability test showed that bubbles with diameters of 1.0, 1.5, and 2.0 mm significantly decreased the viability of PMVECs after contacting 1, 2, 3, and 4 h (allP<0.01). However, the cell damage of PMVECs was obvious only when the 2.0 mm diameter bubble was touched for more than 3 h. The cell viability was (84.27±1.35)% when the bubble with diameter 2.0 mm contacted the PMVECs for 3 h. Conclusion This study establishs a stable cell bubble contact injury model, which can be used to study bubble- related diseases such as decompression sickness. In addition, for PMVECs, 3 h of bubble contact with a diameter of 2.0 mm is the optimal condition for bubble-induced injuries.

    Reference
    Related
    Cited by
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:May 15,2023
  • Revised:June 21,2023
  • Adopted:
  • Online: November 30,2023
  • Published: November 20,2023
Article QR Code