Abstract:Objective To evaluate the professional adaptability of different large language models(LLMs) in generating recommendations for perioperative lung-protective ventilation. Methods A cross-sectional study was conducted using Lung-protective ventilation for the surgical patient: international expert panel-based consensus recommendations published in 2019 as the standard. Eight LLMs were selected to generate ventilation strategy recommendations via standardized prompts. Outcomes were calibrated through assessment by the 8 LLMs and anesthesiologists based on total disagreement score(TDS) and quality assessment of medical artificial intelligence(QAMAI). Results Recommendations generated by LLMs showed strong alignment with the expert consensus but failed to achieve full concordance across all items. Assessment results by LLMs indicated that Chat GPT o1 performed best(TDS 1.5 [1.0, 2.0], QAMAI score 25.5 [22.2, 27.8]), while Gemini 2.0 pro showed the poorest performance(TDS 3.0 [2.0, 5.0], QAMAI score 21.0 [16.8, 23.8]). Among domestic LLMs, DeepSeek R1 achieved the best scores(TDS 2.0 [1.5, 2.8], QAMAI score 25.5 [19.2, 28.2]). Peer review results by anesthesiologists were consistent with LLM assessment findings. Conclusion The recommendations of LLMs for perioperative lung-protective ventilation strategies exhibit heterogeneity, with Chat GPT o1 and DeepSeek R1 demonstrating relatively higher accuracy and potential clinical utility.