【打印本页】 【下载PDF全文】 【HTML】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 2179次   下载 3070 本文二维码信息
码上扫一扫!
钝头针无损伤缝合阴茎背深静脉复合体在腔镜前列腺癌根治术中的 应用
张超,王辉清,过菲,杨波,孙颖浩*
0
(第二军医大学长海医院泌尿外科, 上海 200433
共同第一作者
*通信作者)
摘要:
目的 探讨钝头针无损伤缝合阴茎背深静脉复合体在腔镜前列腺癌根治术中的安全性和有效性。方法 回顾2012年1月至2014年7月,我院同一位医生开展的腹腔镜前列腺癌根治术和机器人辅助腹腔镜前列腺癌根治术,临床资料对病例及手术录像进行回顾性研究,分析缝合阴茎背深静脉复合体时使用的缝针、进出针点的暴露情况、背深静脉出血及误扎导尿管的例数,分析术后前列腺尖部切缘阳性的例数,随访术后3个月患者尿控情况。结果 共104例腔镜前列腺癌根治术患者纳入研究。56例患者采用常规缝针缝扎阴茎背深静脉复合体,其中52例患者可清晰分离出前列腺尖部和膜部尿道连接处的解剖标记"黄金眼";48例患者采用钝头针无损伤缝合,其中44例患者可分离 "黄金眼"。采用钝头针进行无损伤缝合,缝扎及剪断尿道时患者出血量减少、尿控恢复较好(P<0.05)。结论 在准确定位解剖标志"黄金眼"的前提下,采用钝头针缝合阴茎背深静脉复合体可完全阻断阴茎背深静脉复合体,减少患者出血量,保持分离尿道时良好术野,利于术后控尿恢复。
关键词:  前列腺肿瘤  前列腺癌根治术  腹腔镜手术  机器人手术  背深静脉复合体
DOI:10.3724/SP.J.1008.2015.00439
投稿时间:2014-11-26修订日期:2015-01-27
基金项目:第二军医大学长海医院学科重点发展基金.
Application of blunt-tip needle to suture dorsal venous complex in laparoscopic radical prostatectomy
ZHANG Chao,WANG Hui-qing,GUO Fei,YANG Bo,SUN Ying-hao*
(Department of Urology, Changhai Hospital, Second Military Medical University, Shanghai 200433, China
Co-first authors.
*Corresponding author)
Abstract:
Objective To evaluate the safety and efficacy of using blunt-tip needle to suture the dorsal venous complex (DVC) in laparoscopic radical prostatectomy. Methods The clinical data and the operation videos of patients, who received laparoscopic and robot-assisted radical prostatectomies by a single surgeon in our hospital from Jan. 2012 to Jul. 2014, were retrospectively reviewed. The needles used to suture DVC, exposure of suture points, bleeding of DVC, and cases of mistakenly sutured catheter and positive margins at the epic were analyzed. Continence of patients was followed and analyzed 3 months after surgery. Results A total of 104 cases were enrolled in this study. DVC was sutured with traditional needles in 56 cases, and in 52 of them the junction between prostate epic and membranous urethra (so called golden eye) could be exposed. DVC was sutured with blunt-tip needles in 48 cases, and the "golden eye" could be found in 44 of them. Suturing with blunt-tip needles, compared with traditional needles, resulted in significantly less bleeding and significantly better continence recovery (P<0.05). Conclusion Dorsal venous complex can be completely sutured by using blunt-tip needle once the "golden eye" is correctly indentified, which can decease the intraoperative bleeding and maintain a clear surgical field, improving the postoperative continence recovery.
Key words:  prostatil neophasms  radical prostatectomy  laparoscopic surgery  robotic surgery  dorsal venous complex