【打印本页】 【下载PDF全文】 【HTML】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 1807次   下载 95  
第三代脊柱内固定系统在成人脊柱侧凸中应用的疗效评价
李明,刘洋,倪春鸿,朱晓东,白玉树,赵新刚,侯铁胜
0
()
摘要:
目的:回顾分析TSRH、CD、Isola等第三代脊柱内固定系统在成人脊柱侧凸矫治中的应用并评价其疗效.方法:分析运用TSRH、CD、Isola脊柱内固定系统治疗的35例成人脊柱侧凸患者.术前冠状面主弯Cobb角平均58.1° (42°~95°),采用前后路联合矫形或单纯后路矫形手术方法.平均随访20个月(10~48个月).通过影像学资料对术前术后冠状面和矢状面的矫形效果对比分析并通过C7椎体中点距骶中线(CVSL)的距离来分析躯干平衡的重建,通过关于自我评估的问卷调查来获得患者主观治疗效果评价. 结果:所有患者术后外观矫形效果明显(P<0.05).总体冠状面主弯平均Cobb角矫正53.2%.末次随访冠状面Cobb角平均丢失4.3°.C7中点距CVSL由术前的平均2.6 cm矫正为术后的0.24 cm.通过随访期间的问卷调查89.3%以上的患者对外观改善、疼痛的缓解表示满意,2例术气胸、血胸,3例术后随访1年后仍主诉腰背部疼痛,其中2例为临近节段退变,1例为假关节形成. 结论:对于成人脊柱侧凸,第三代脊柱内固定系统能得到冠状面上较高的矫正率、重建躯干平衡,并且可以获得患者较高的满意度,并发症较少.
关键词:  脊柱侧凸、成年人、内固定器、脊柱
DOI:
基金项目:
Efficacy of the third-generation instrumentation for treatment of adult scoliosis
李明,刘洋,倪春鸿,朱晓东,白玉树,赵新刚,侯铁胜
()
Abstract:
Objective: To evaluate the efficacy of the third-generation instrumentation including TSRH, CD and ISOLA in the treatment of adult scoliosis. Methods:Thirty-five adult patients with idiopathic or degenerative scoliosis who received treatment with third-generation instrumentation (TSRH,CD and ISOLA) between July 1999 to January 2003 were retrospectively reviewed. The mean preoperative cobb angle of major curves of the frontal plane was 58.1°(42°-95°). The patients received a combined anteroposterior approach or a single posterior procedure. The mean follow-up time was 20 months(10-48 months). Preoperative and postoperative Cobb angles of the frontal plane and sagittal plane and the distance between C7 and CVLS were measured. The subjective assessment was judged by questionnaire. Results: Postoperative clinical appearance of all patients improved significantly. Mean correction of major curves of the coronal plane was 53.2%. Mean loss of correction of the coronal plane in the last follow-up was 4.3°. The distance between the midline of C7 and CVSL was corrected from 2.6 cm to 0.24 cm. The results of follow-up showed that 89.3% patients were satisfied with the outcome. Pneumatothorax and haematothorax occurred in 2 patients. Three patients still complained of low back pain one year after operation because of adjacent degeneration in 2 patients and pseudoarthrosis in the remaining 1 patient. Conclusion: Imageologic findings and subjective assessment of the patients showed that the third-generation instrumentation can achieve good correction and trunk balance in the treatment of adult scoliosis with fewer complications.
Key words:  scoliosis  adult  internal fixators  spine