【打印本页】 【下载PDF全文】 【HTML】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 3160次   下载 2433 本文二维码信息
码上扫一扫!
非血管超声造影指导下穿刺引流上消化道瘘的初步尝试
宋家琳△,章建全△,赵皓珺,盛建国,卢峰,章建全
0
(第二军医大学长征医院超声科,上海 200003;上海长征医院)
摘要:
目的评价口服和经引流管注射等非血管超声造影在引导穿刺治疗上消化道瘘的价值。方法对食管吻合术和毕Ⅰ式胃吻合术形成的13例胸腔食管瘘、2例腹腔胃瘘合并重症感染的患者进行超声引导下脓肿穿刺引流治疗。穿刺术前、术中行口服超声造影及引流腔注射造影,明确瘘腔位置,确定安全穿刺路径,进行彻底引流。结果13例患者于穿刺术前口服超声造影剂,均明确了真正瘘腔的具体位置,其中2例患者因缺乏安全穿刺路径未能实施穿刺治疗;穿刺术中口服超声造影剂可持续强化穿刺目标,增强穿刺针前进的方位感和准确性;引流腔注射造影可评价穿刺定位的准确性、引流管前端位置是否恰当及干预的有效性。结论非血管超声造影技术对超声引导下上消化道瘘的微创穿刺治疗具有指导价值,弥补了常规超声成像的不足。
关键词:  胸腔食管瘘  腹腔胃瘘  脓毒症  引流术  口服超声造影
DOI:10.3724/SP.J.1008.2010.0753
投稿时间:2010-04-02修订日期:2010-05-10
基金项目:第二军医大学长征医院“三重三优”学科和人才建设专项基金.
Values of non-vascular contrast-enhanced ultrasound in guiding percutaneous drainage of upper gastrointestinal fistulas
SONG Jia-lin△, ZHANG Jian-quan△, ZHAO Hao-jun, SHENG Jian-guo, LU Feng,zhang jian quan
(Department of Ultrasonics, Changzheng Hospital, Second Military Medical University, Shanghai 200003, China)
Abstract:
ObjectiveTo assess the value of non-vascular contrast-enhanced ultrasound(oral contrast-enhanced ultrasound, fistula cavity contrast-enhanced ultrasound, etc.) in guiding percutaneous drainage of the upper gastrointestinal fistulas.MethodsThirteen patients with suppurative pleuro-esophageal fistulas following esophagus-anastomosis/Billroth Ⅰ stomach-anastomosis and two patients with gastric fistulas combined with severe infection underwent percutaneous drainage.Before and during the procedure, oral contrast-enhanced ultrasound and fistula cavity contrast-enhanced ultrasound scanning were conducted to identify the position of fistulas, determine the safe approach for a radical catheterization drainage.ResultsThe actual positions of the upper gastrointestinal fistulas in the 13 patients were identified for puncturing after preoperative oral contrast-enhanced ultrasound.Two of the 13 patients did not receive puncturation due to lack of safe approach.During the operation, oral contrast-enhanced ultrasound maintained the fistula cavity enhanced for a long time, ascertaining a safe approach.Fistula cavity contrast-enhanced ultrasound could be used to evaluate the accuracy of percutaneous drainage, ascertain the location of catheter tip for more effective drainage, and estimate the efficacy of interventions.ConclusionNon-vascular contrast-enhanced ultrasound is valuable in guiding percutaneous drainage for upper gastrointestinal fistulas, which makes for the shortcomings of the conventional ultrasonic imaging.
Key words:  pleuro-esophageal fistula  coelio-stomachal fistula  sepsis  drainage  oral contrast-enhanced ultrasound