【打印本页】 【下载PDF全文】 【HTML】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 1384次   下载 1172 本文二维码信息
码上扫一扫!
高效液相色谱-紫外检测法同时测定染发剂中的20种染料成分
钱跹,金柔男,赵亮,吕磊,张海,李悦悦,张国庆*
0
(第二军医大学东方肝胆外科医院药材科, 上海 200438
*通信作者)
摘要:
目的 建立高效液相色谱(HPLC)-二极管阵列检测器(DAD)法测定染发剂中20种染料成分的含量,对《化妆品卫生规范》中的氧化型染料的HPLC检测方法进行改进和补充。 方法 样品经乙醇-水超声提取,过滤后进样检测。色谱柱:Agilent Zorbax Bonus-RP (4.6 mm×250 mm,5 μm); 流动相:A相为乙腈,B相为4 mmol/L磷酸盐缓冲液(pH 6.0,含0.1%的辛烷磺酸钠离子对试剂),梯度洗脱:0~24 min,10% A; 24~26 min,10%~40% A; 26~45 min,40% A; 45~47 min,40%~80% A; 47~52 min,保持80% A不变; 流速1 mL/min; 柱温15℃,使用DAD进行检测,检测波长为280 nm,进样量5 μL。 结果 各染料成分在50 min内基线分离。在10.0~500.0 mg/L浓度范围内,线性关系良好,相关系数均高于0.999。日内及日间精密度均小于4%,加样回收率为81.90%~119.88%。 结论 该方法简便、快速、准确,适于氧化型染发剂中染料成分的检测。
关键词:  高压效液相色谱法  染料  染发剂
DOI:10.3724/SP.J.1008.2014.00110
投稿时间:2013-07-10修订日期:2013-09-09
基金项目:
HPLC-DAD for simultaneous determination of 20 colorants in hair dyes
QIAN Xian, JIN Rou-nan, ZHAO Liang, LÜ Lei, ZHANG Hai, LI Yue-yue, ZHANG Guo-qing*
(Department of Pharmacy, Eastern Hepatobiliary Surgery Hospital, Second Military Medical University, Shanghai 200438, China
*Corresponding author.)
Abstract:
Objective To develop a high-performance liquid chromatography (HPLC)-diode array detector (DAD) method for determination of 20 colorants in hair dyes, so as to improve the method for determining oxidative hair dyes in Hygienic Standard for Cosmetics. Methods After ultrasonic extraction with ethanol-water, samples were analyzed by HPLC. The separation was achieved on an Agilent Zorbax Bonus-RP column (4.6 mm×250 mm,5 μm) using a gradient mobile phase system of A: acetonitrile and B: 4 mmol/L PBS (pH=6.0) containing 0.1% 1-octanesulfonic acid sodium salt solution at a flow rate of 1 mL/min. The gradient elution program was as follows: 0-24 min, 10% A; 24-26 min,10%-40% A; 26-45 min,40% A; 45-47 min,40%-80% A; 47-52 min,keep 80% A unchanged. The detection wavelength was set at 280 nm,the temperature of column was 15℃, and the injection volume was 5 μL. Results All the components were separated at baseline within 50 min. Within the concentration range of 10.0-500.0 mg/L, the peak areas and concentrations of colorants had good linear relationship, with the linear correlation coefficients being higher than 0.999. The intra-day and inter-day precisions were within 4% and the average recoveries ranged from 81.90% to 119.88%. Conclusion The present method is simple, rapid and accurate and is suitable for determination of colorants in oxidative hair dyes.
Key words:  high pressure liquid chromatography  colorants  hair dyes